Atlas Copco Stationary Air CompressorsGA5-7-11C-11-15-18-22-30C-30-37-45-55C-55-75-90C andGA30 W-37 W-45 W-55C W-55 W-75 W-90C WWith Elektronikon I or

Seite 2 - OWNERSHIP DATA

2920 1461 038User manual°C82°C4Bar7.0kHrsr001kHrs4.039r003kHrs3.1613158kHrs4.002kHrs"4.002"r004kHrsr002kHrsr005KLbarP001°CP003kHrsP004°C

Seite 3

2920 1461 039User manualParameter Used forscreensP001 Unload pressure settingP002 Load pressure settingP003 Warning level setting for dewpoint tempera

Seite 4 - Contents

2920 1461 0310User manual1. Press arrow key (12) until r002 is shown and then pressenter key (5):kHrs1.755The screen shows the unit used (kHrs or

Seite 5 - ELEKTRONIKON I REGULATOR

2920 1461 0311User manual7.7 Set of parametersStarting from the Main screen:bar6.6Press arrow key (12) until r007 is shown and press enter key(5)

Seite 6 - 3 Display

2920 1461 0312User manual1. Press arrow key (12) until P003 is shown and press enterkey (5):°C8The screen shows the warning setting for the

Seite 7 - 4 Shut-down warning

2920 1461 0313User manual1. Press arrow key (12) until P007 is shown and press enterkey (5). The actually used starting mode is blinking: 1for Y-D

Seite 8 - 5 Shut-down

2920 1461 0314User manual8 Settings8.1 Unloading/loading pressuresMinimum Nominal MaximumUnloading pressure13 bar . . . . . . . . . . . . . . . . . .

Seite 9 - 6 Service warning

2920 1461 0315User manualPART 2ELEKTRONIKON II REGULATOR- On GA Workplace FF with ICD the inlet temperature of thecompressed air into the dryer exceed

Seite 10 - Simplified menu flow

2920 1461 0316User manual2 Control panel2.1 LEDs/buttons/keysRef. Designation Function1 Stop button Push button to stop thecompressor. LED (8)

Seite 11 - 2920 1461 03

2920 1461 0317User manual2.2 Pictographs10 Alarm11 Automatic operation12 Voltage on2.3 Function keysThe keys are used:- To manually load/unload the co

Seite 12 - 7.4 Calling up motor starts

Compressor type: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unit serial No. compressor: . . . . . . . . . . . .

Seite 13

2920 1461 0318User manualCompr Outletbar 7.0Auto Loaded↓Menu UnldAuto Operation Local ControlTimer Active↓Main Help XtraMax Pressure ↑bar 7.5↓Mai

Seite 14 - 2920 1461 03

2920 1461 0319User manualFig. 3.1b Simplified menu flow of GA Workplace Full-Feature with ICDCompr Outletbar 7.0Auto Loaded↓Menu UnldAuto Operation Lo

Seite 15

2920 1461 0320User manual3 Menu-driven control programsTo facilitate programming and controlling the compressor,menu-driven programs are imp

Seite 16 - 8 Settings

2920 1461 0321User manual4 Quick look at actual compressorstatusProcedure1. Starting from the Main screen (see section 3.2), press the ¯key: A sc

Seite 17 - ELEKTRONIKON II REGULATOR

2920 1461 0322User manualShut-down reset1. Switch off the voltage and remedy the trouble. Afterremedying and when the shut-down condition

Seite 18 - 2 Control panel

2920 1461 0323User manual6 Measured data menuFunctionTo call up information regarding the actually measured dataand the status of some inputs su

Seite 19 - 2.3 Function keys

2920 1461 0324User manual2. The screen shows that the current setting is 6.0 bar(e). Tomodify this setting, press the key Mod (F2):Loading PressBa

Seite 20

2920 1461 0325User manual11.1 Modifying settings for compressorelement1. Consult the section above to select the parameter Elementoutlet:Element Ou

Seite 21

2920 1461 0326User manualProcedure1. Starting from the Main screen (see section 3.2):- press the key Menu (F1)- press the ¯ key until the opti

Seite 22

2920 1461 0327User manual6. Press the ¯ key: the right pointing arrow key indicates thatthe second line is accessible. Press the key Mod andmo

Seite 23 - 5 Status data menu

Atlas Copco Stationary Air CompressorsImportantThis book applies exclusively to the above-mentioned compressors withElektronikon I or II regulator fro

Seite 24 - 5.5 A warning message exists

2920 1461 0328User manual5. If necessary, press the tabulator key (5) to go to the nextfield to be modified, the minutes indication and th

Seite 25 - 9 Modify params menu

2920 1461 0329User manual14 Configuration menuFunctionTo reprogram a number of parameters. See Figs. 3.1.Procedure1. Starting from the Main screen (s

Seite 26 - 10 Modifying parameters

2920 1461 0330User manualProcedure1. Starting from the Main screen (see section 3.2):- press the key Menu (F1)- press the ¯ key until the option S

Seite 27 - 12 Modifying service plans

2920 1461 0331User manual17 Programmable settings17.1 ParametersMinimum Nominal MaximumMotor running time in star . . . . . . . . . . . . . . . . . .

Seite 28 - 13 Programming Clock function

2920 1461 0332User manualUnloading/loading pressures for GA Workplace Full-Feature with ICDDewpoint -40° variant 50HzCombination UNLOADING LOADINGGA

Seite 29

2920 1461 0333User manualCombination UNLOADING LOADINGGA and ICDGA Model ICD model Minimum Nominal Maximum Minimum Nominal MaximumUnloading Unloading

Seite 30 - 13.5 To delete commands

2920 1461 0334User manualCombination UNLOADING LOADINGGA and ICDGA Model ICD model Minimum Nominal Maximum Minimum Nominal MaximumUnloading Unloading

Seite 31 - 15 Service menu

2920 1461 0335User manualDewpoint -70° variant 50HzCombination UNLOADING LOADINGGA and ICDGA Model ICD model Minimum Nominal Maximum Minimum Nominal M

Seite 32 - 16 Saved data menu

2920 1461 0336User manualDewpoint -70° variant 60HzCombination UNLOADING LOADINGGA and ICDGA Model ICD model Minimum Nominal Maximum Minimum Nominal

Seite 33 - 17 Programmable settings

2920 1461 0337User manual17.2 ProtectionsMinimum Nominal MaximumCompressor element outlet temperature 4) . . . . . . . Celsius 9) 110 119(shut-down w

Seite 34

2920 1461 032User manualPage7 Scrolling through all screens . . . . . . . . . . . . . . . . . . . . . . . . . 77.1 Calling up outlet/dewpoint temper

Seite 35

2920 1461 0338User manualNotes:...

Seite 36

2920 1461 0339User manualNotes:...

Seite 37

2920 1461 0340User manualNotes:...

Seite 38

14. If the ground is not level or can be subject to variable inclination,consult Atlas Copco.15. The electrical connections shall correspond to the lo

Seite 39 - 17.3 Service plan

No. 2920 1461 03 / DC2003-09What sets Atlas Copco apart as a company is ourconviction that we can only excel in what we do if weprovide the best possi

Seite 40

2920 1461 033User manualPART 1ELEKTRONIKON I REGULATOR1.3 Automatic restart after voltage failureFor compressors leaving the factory, this functi

Seite 41

2920 1461 034User manualRef. Designation Function4 Reset key Key to reset the service timer, ashut-down condition, etc.5 Enter key Key to select

Seite 42

2920 1461 035User manualImportantAlways consult Atlas Copco in case "t" or "test" appears on thedisplay3.3 Scrolling through all s

Seite 43 - Maintenance

2920 1461 036User manual5 Shut-downThe compressor will be shut down in case:- the temperature at the outlet of the compressor elementexceeds th

Seite 44 - *2920146103*

2920 1461 037User manual6 Service warningA service warning will appear when the service timer hasreached the programmed time interval.1. In case the s